Reports room temperature? Yes / No
Screen: Room Devices — air conditioner card, System = IR sent by Crestron.
What it is
Says whether the Crestron processor also sends the room's temperature for this AC.
What to enter
Press Yes only if the processor has the room temperature on an analog join. No is the default.
What it changes
In the house: Saved in the project at once. It reaches the house and the phones at the next Save & Deploy. With Yes and a join, the hub reads the room temperature from that join. With No, nothing is sent, even if a join was typed.
In the app: With Yes, the AC tile shows a Room temperature cell.
If it goes wrong
- Yes with no join: no temperature is sent and the Room cell stays empty.
- The hub reads the join as tenths of a degree (245 = 24.5°). That scale still waits for a ruling; if the number looks ten times wrong, tell the LuxeLife team.